White rodgers 50t35 manual3/6/2024 If the fault is internal to the control, the light will stay off. If a fault occurs, the LED will indicate a fault code as shown below. The 50T35-743 control continuously monitors its own operation and the operation of the system. The blower off delay in the cooling mode is (60) seconds and is non-adjustable.Ĭaution is to be exercised not to bend the metal pins when changing the time delay from the factory setting. The blower on time in the cooling mode is (5) seconds and is non-adjustable. The blower on time in the heating mode is (30) seconds and is non-adjustable. If the jumper is removed, the control will default to a (150) second blower off delay in the heating mode. See drawing below for the jumper position for all available settings: The control is factory set to give a (150) second blower off delay. See the drawing below for the location of this jumper. ![]() This can be accomplished by changing the position of a plastic jumper located on the ignition control. In the heating mode, the blower off delay can be selected to obtain a 90, 120 or 150 seconds period.